A bed that has a complete washable solution.The acuity-adaptive hospital bed ensures compliance with the highest standards of hygiene in a variety of designs.The lateral tilt is becoming a new standard in acute care, reducing physical strain on the carer on the 67%.
Technical data:
| Parameter | Meaning. |
| External bed length | 219 cm (221 cm for bed with auxiliary adapter with 2 bushings for the headboard lift post) |
| External bed width | 99.5 cm |
| Maximum height of the handrail above the mattress support platform: with plastic sides with telescopic side handrails |
42cm |
| Dimensions of the side handrails (length x height): side handrails made of plastic (side handrails for the head; side footrails) telescopic side handrails (main handrail; footrail) folding handrails |
101.3 cm;88.5 cm x 43.5 cm 100 cm; 100 cm x 43 cm |
| Maximum mattress dimensions (length x width) | 200 cm x 90 cm |
| Maximum mattress height: with plastic side rails with telescopic side handrails |
20 cm 20 cm |
| Bed extension | 0 cm / 20 cm / 30 cm |
| Calfrest expansion | 0 cm - 20 cm |
| Wheel diameter: |
12.5 cm |
| 125 Double wheel Tente Linea | |
| 150 Tente Linea double wheel | 15 cm |
| 150 Simple Tente Integral wheel | 15 cm |
| Simple wheel Tente Integral Soft Brake 150 | 15 cm |
| Minimum - Medium - Maximum mattress support platform height above the floor (without mattress): |
25.5 cm - 37.4 cm - 75.9 cm |
| Essenza 300 with 125 Tente Linea double castors | |
| Essenza 300 with 150 Tente Linea double castors | 25.5 cm - 37.4 cm - 75.9 cm |
| Maximum clearance under the undercarriage in standard position (with Tente Linea 125 double castors) | 14.1 cm |
| Maximum undercarriage clearance in standard position (with 150 Tente Linea double castors) | 16.6 cm |
| Maximum tilt angle of the backrest | 70° |
| Maximum hip angle | 35° |
| Maximum Calfrest angle | 25° |
| Maximum lateral tilt angle | 15° |
| Maximum angle between Calfrest and Thighrest | 300° |
| Distance to Ergoframe (distance to backrest / distance to hips) | 5 cm / 3 cm |
| Maximum tilt angle of the Trendelenburg | 14° |
| Maximum reverse tilt angle of the Trendelenburg | 14° |
| Average bed weight | 165 kg |
| Maximum load on the support | 75 kg |
| Safe working load (SWL) | 300 kg |
| Maximum weight of the mobile hospital bed (maximum weight of the empty bed + safe working load) | 485 kg |
| Maximum patient weight Field of application 1, 2 Field of application 3, 5 |
235 kg 265 kg |
| Maximum sound pressure level | 53 dBA |