Medical bed Essenza 300 W

Manufacturer: LINET spol. s r.o.
Country: Czech Republic

Medical bed Essenza 300 W

Order

A bed that has a complete washable solution.The acuity-adaptive hospital bed ensures compliance with the highest standards of hygiene in a variety of designs.The lateral tilt is becoming a new standard in acute care, reducing physical strain on the carer on the 67%.

Technical data:

Parameter Meaning.
External bed length 219 cm (221 cm for bed with auxiliary adapter with 2 bushings for the headboard lift post)
External bed width 99.5 cm
Maximum height of the handrail above the mattress support platform:
with plastic sides
with telescopic side handrails
 

42cm
43cm

Dimensions of the side handrails (length x height):
side handrails made of plastic (side handrails for the head;
side footrails) telescopic side handrails (main handrail; footrail) folding handrails
 

101.3 cm;88.5 cm x 43.5 cm

100 cm; 100 cm x 43 cm

Maximum mattress dimensions (length x width) 200 cm x 90 cm
Maximum mattress height:
with plastic side rails
with telescopic side handrails
20 cm
20 cm
Bed extension 0 cm / 20 cm / 30 cm
Calfrest expansion 0 cm - 20 cm
Wheel diameter:  

12.5 cm

125 Double wheel Tente Linea
150 Tente Linea double wheel 15 cm
150 Simple Tente Integral wheel 15 cm
Simple wheel Tente Integral Soft Brake 150 15 cm
Minimum - Medium - Maximum mattress support platform height above the floor (without mattress):  

25.5 cm - 37.4 cm - 75.9 cm

Essenza 300 with 125 Tente Linea double castors
Essenza 300 with 150 Tente Linea double castors 25.5 cm - 37.4 cm - 75.9 cm
Maximum clearance under the undercarriage in standard position (with Tente Linea 125 double castors) 14.1 cm
Maximum undercarriage clearance in standard position (with 150 Tente Linea double castors) 16.6 cm
Maximum tilt angle of the backrest 70°
Maximum hip angle 35°
Maximum Calfrest angle 25°
Maximum lateral tilt angle 15°
Maximum angle between Calfrest and Thighrest 300°
Distance to Ergoframe (distance to backrest / distance to hips) 5 cm / 3 cm
Maximum tilt angle of the Trendelenburg 14°
Maximum reverse tilt angle of the Trendelenburg 14°
Average bed weight 165 kg
Maximum load on the support 75 kg
Safe working load (SWL) 300 kg
Maximum weight of the mobile hospital bed (maximum weight of the empty bed + safe working load) 485 kg
Maximum patient weight
Field of application 1, 2
Field of application 3, 5
235 kg
265 kg
Maximum sound pressure level 53 dBA
Manufacturer

LINET spol. s r.o.

Country.

Czech Republic